EA Prerequisite 2:
Minimum Energy Performance Requirement:
Option 1: Demonstrate a 10% improvement in the proposed building performance rating for new buildings, or a 5% improvement in the proposed building performance rating for major renovations to existing buildings, compared with the baseline building performance rating determined by ASHRAE 90.1-2007.
|
EA Credit 1:
Optimize Energy Performance Requirement:
- New Construction & Schools: 1-19 Points
- Core and Shell: 3-21 Points
- Healthcare: 1-24 Points
Option 1: Demonstrate a percentage improvement in the proposed building performance rating compared with the baseline building performance rating as determined by Appendix G of ANSI/ASHRAE/IESNA Standard 90.1-2007. (New buildings: 12% improvement; Existing building renovations: 8% improvement |
Solution:
Furniture mounted task lighting that includes a control device (e.g. switch) either integrated into the fixture or a nearby wall should typically be included in the baseline lighting power allowance (LPA) calculation. By connecting this type of task lighting to a plug load control device offering automatic shutoff, you can exclude it from the LPA calculation for the proposed building thereby improving building performance.
Isolé and DLM occupancy-based controls providing automatic shutoff can help improve building performance.
|
|
| |